Single V3 Pump & Sump from PPS
Single pump packaged pump station designed to be used where running water is not present or expected, in smaller basements for protection only.
PPS Single V3 Pump Station
The PPS Single V3 pump station is the smallest packaged pump system in the PPS range, designed for use below ground in smaller basements or areas where running water is not present or expected. An entry level protective system with the highly reliable V3 Pump capable of pumping 120 litres of water per minute at a 3.5m head.
This Single V3 pump system can be used to collect water in non habitable spaces such as smaller cavity drain systems, sunken gardens and vaulted storage areas. We do not suggest this system is used in habitable spaces. For this we recommend the PPS Dual V3 Pump Station.
Note: This Single V3 pump station cannot be used to collect grey water from sinks, showers or washing machines. For this application we suggest the use of the Foul V3 Pump Station.
What’s included in a PPS Single Sump Pump System
- HDPE Chamber - capable of withstanding hydrostatic water pressure
- Powerful V3 Pump - capable of removing 2 litres per second @ a 3.5m head
- Internal pipework - pre glued off site for easy on site installation
- External outlet - pre connected outlet for waste water
- Cable inlet - pre connected cable inlet for pump power and optional Alertmaxx 2 alarm switch
Note: this system is not supplied with a lid.
Benefits of a PPS V3 Pump Sump System
- Smallest sump chamber in the range
- Chamber made from robust HDPE
- Powerful V3 Pump
- Supplied as kit with all preglued internal pipework
- Waste Water outlet and cable inlet pre installed onto the sump
Installing a single V3 Pump Sump system
The sump chamber should sit on a concrete base and receive all inlets from your perimeter drainage system as well as:
- 32mm discharge pipe to connect to the gravity drain
- 50mm cable duct for electrics & control cabling
The sump chamber needs to be set in place with concrete. Fill the sump chamber with water first in order to prevent buoyancy when pouring the concrete. You want to ensure that the top of the sump is level with the structural slab or no deeper than 500mm from the final finishes.
A double sealed cover is recommended to complete installation and compliment the general floor finish (not supplied).
NOTE: This Pump Sump Systems needs to be accessible for service so carefully consider its location within your design.
For more information on sump pump systems, read our guide to sump pump installation.
Permagard - Providing Solutions. Inspiring Confidence.
If you have any technical questions about PPS sump pump systems, call our expert team on 0117 982 3282. Find out more about PPS - Pumps or browse our full range of basement sump pumps.
Features
- Smallest sump chamber in the range
- Chamber made from robust HDPE
- Powerful V3 Pump - 120l/m @ 3.5m head
- Supplied as kit with all preglued internal pipework
- Waste water outlet and cable inlet pre installed onto the sump
Dual Pump & Sump from PPS
Prices from